Below is a list of common fault alarm codes for your Clenergy Solar Inverter Model Number SPH15/SPH20/SPH30/SPH40 and SPH60, followed by helpful solutions
Fault Readings | Solutions |
---|---|
No Utility | Check grid voltage by multi-meter, check grid connection and check breaker between inverter and grid |
Grid Fault | Check grid voltage and frequency by multi-meter |
Impedance Fault | Check the wires between inverter and grid |
Isolation Fault | Check the impedance between PV+ and PV- and earth ground |
Ground I Fault | Check the AC wiring and connection system |
Over Temperature | Reduce ambient temperature |
PV Over Voltage | Check the PV open-circuit voltage – should be less than 500Vdc |
Device Fault | Disconnect PV+ and PV- from the input and start up the unit again |
Consistent or Mismatch Fault | Disconnect PV+ and PV- from the input and start up the unit again |
Please note that these are general tips only and are based on our current and past experience and therefore, not specific to your solar inverter problem. What we usually find is people trying these troubleshooting tips and if these fail, they give us a call and we can perform diagnostic tests. What we usually find is people trying these troubleshooting tips and if these fail, they give us a call and we can perform diagnostic tests and provide a solution.